Product Center

+
  • 9c288bf1-6dde-4485-b7c2-240647054fd1(2).jpg

U2829A Precision LCR Meter


Test frequency: 20Hz–300kHz
Basic accuracy: 0.05%
Test level: 5 mV-2V(standard);5mV–10V(enhanced)
Test speed: Fast: 9, Med: 67, Slow:187 (ms/time)
Internal bias: -5V – +5V
Output Impedance: 10Ω/CC , 25Ω ,50Ω , 100Ω

keywords: LCR Meter Capacitance Meter

File:


Category:

product details


  • 产品描述
  • Technical parameters
  • Order information
  • Instrument accessories
  • Optional accessories
  • Video data
    • Commodity name: U2829A Precision LCR Meter
    • Commodity ID: 1070400215375826944

    Test frequency: 20Hz–300kHz<BR> Basic accuracy: 0.05%<BR> Test level: 5 mV-2V(standard);5mV–10V(enhanced)<BR> Test speed: Fast: 9, Med: 67, Slow:187 (ms/time)<BR> Internal bias: -5V – +5V<BR> Output Impedance: 10Ω/CC , 25Ω ,50Ω , 100Ω

    Brief Introduce:

    U2829 Series LCR Meter is a new generation of impedance test equipment with high accuracy, wide measurement range and six digits resolution. Being possessed with test frequency of 20Hz-1MHz, test voltage of 5mV~10V and built-in typical DC bias, it can meet all requirements for measuring components and materials and provide guarantees for production line quality assurance, incoming inspection and laboratory precision measurements. Otherwise, the Handler, RS232C and GPIB interfaces as well as improved command system provided by the instrument make it easier to build the test system.

    Features:

    ■ 7-inch 16:9 TFT LCD display and resolution of 800*480

    ■ Max. Test frequency: 1MHz; resolution: 1mHz

    ■ Max. Test speed: 9ms/time

    ■ Test signal level: 5 mV-2V(standard);5mV – 10V(enhanced)

    ■ Basic Accuracy:0.05%

    ■ Continuous curve scanning/Graphic analysis function

    ■ Open/short/load correction

    ■ Optional ±100mA, ±10V bias voltage source, 0–1A bias current

    ■ Internal storage: 100 groups; External storage and recall: 500 groups

    ■ Test data and screen graphs can be saved to U-disk in several formats

    ■ Multiple file search modes: fuzzy search, accurate search and bar-code search

    ■ Abundant interfaces:RS232C, USBTMC, USBCDC, HANDLER, GPIB

    ■ Be equipped with BNC trigger to realize external foot switch connection In accordance with LXI standard and rapid building of test system

    General Specifications:

    Temperature & Humidity 0°C-40°C,  ≤90%RH
    Power Requirements Voltage 198V-242V or 99V - 121V
    Frequency 47.5Hz-63Hz
    Power ≤ 80 VA
    Dimension(W×H×D) 400mm×132mm×350mm
    Weight approx. 10.0kg
  • System Specifications
    Test Frequency and Function U2829A 20Hz – 300kHz Continuous frequency,resolution:1mHz
    U2829B 20Hz – 500kHz
    U2829C 20Hz – 1MHz
    Measurement function
    LCR Test parameter |Z|, |Y|, C, L, X, B, R, G, D, Q, θ ,DCR
    Basic Accuracy 0.05%
    Measuring speed(≥10kHz) Fast: 9, Med: 67, Slow:187 (ms/time)
    Equivalent circuit Series and Parallel
    Ranging mode Auto, Hold
    Trigger mode Internal, Manual, External and Bus
    Average numbers 1—255
    Delay time 0—60s, 1ms step
    Correction Open/short, dot frequency, full frequency, load
    List sweep 40 points frequency, level, bias voltage/current
    Graphic Scanning Frequency, level, bias voltage / current
    Test signal
    Test signal level 5 mV-2V(standard);5mV – 10V(enhanced), Auto level range:5 mV-1 V  Accuracy:5% , Resolution:1mV
    Output Impedance 10Ω/CC , 25Ω ,50Ω , 100Ω
    DC bias (internal) -5V – +5V (continuous),Accuracy:1%
    Measurement display range
    |Z|, R, X 0.00001 Ω — 99.9999 MΩ
    DCR 0.00001 Ω — 99.9999 MΩ
    |Y|, G, B 0.00001µS — 99.9999 S
    C 0.00001 pF — 9.9999 F
    L 0.00001 µH — 99.9999 kH
    D 0.00001 — 9.99999
    Q 0.00001 — 99999.9
    θ (DEG) -179.999º — 179.999 º
    θ (RAD) -3.14159 — 3.14159
    Δ% -999.999% — 999.999%
    Other
    Comparator 10 bins, bin counter
    Memory Internal storage: 100 groups,External storage: 500 groups
    Interface RS232C,USBTMC, USBCDC, Handler, GPIB(option)
  • U2829A Precision LCR Meter

  • U26005 Four-terminal test fixture U26011 Four-terminal Kelvin test cable U26010 Gilded shorting plate

  • U26006 轴向元件测试夹具(与U26005配合使用)

    U26008 SMD元件测试夹具

    U26009 SMD测试钳

    U10502 100mA/10V 偏流板

    U10501 1A DC偏流板

    U10301 GPIB接口板


Recommended products

U9311 Hipot Tester

Insulation resistance test: No
AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)
DC test: 0.05kV-6kV ±(2% reading+5 digits)
Output channel: 0.05kV – 1kV ±(1.0% reading+2V)
Grouping test function: AC
Interface configuration: PLC,RS232C

U822C Handheld LCR meter

Test frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω

U822A Handheld LCR meter

Test frequency: 100Hz, 120Hz, 1kHz, 10kHz
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω

U822 Handheld LCR meter

Test frequency: 100Hz,120Hz,1kHz
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Mid), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω

Online Message