Product Center
U822C Handheld LCR meter
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
keywords: LCR Meter Capacitance Meter
Category:
Hotline:
product details
- 产品描述
- Technical parameters
- Order information
- Instrument accessories
- Optional accessories
- Video data
-
- Commodity name: U822C Handheld LCR meter
- Commodity ID: 1070412723893456896
Test frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz<BR> Basic accuracy: 0.1%<BR> Test level: 0.6Vrms<BR> Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)<BR> Internal bias: -----<BR> Output Impedance: 100 Ω
Brief Introduction:
Applying the latest impedance measurement technology and ultra-low-power design, EUCOL company released the handheld LCR digital bridge with powerful function, highest precision, fastest speed, longest standby time in the industry. Being equipped with clear and intuitive bright white backlight, clear and intuitive display, concise operating functions, maximum test frequency of 100KHz and high-capacity rechargeable battery, this LCR meter can meet accurate measurement requirements at any occasion. It is the ideal maintenance tool used in laboratories, production lines, maintenance point and teaching for the measurement and screening of inductance, capacitance and resistance.
Features :
■ Basic accuracy: 0.1%
■ Skid-resistant and anti-knock soft sheath
■ Maximum test signal frequency : 100kHz (U822C)
■ Standard bright white backlight make clear and intuitive display
■ 40000 counts for primary parameter, resolution of D/Q: 0.0001
■ Ultra-low power consumption; the power supply can be used for 24 hours of continuous work; standard rechargeable battery
■ Automatic identification (Ai) function can automatically determine and display the component types and measurements
■ Up to 10 times/sec of test speed; the fastest speed in the industry with automatic range design
■ Constant 100 Ohm output impedance
■ 4-level tolerance compare mode:1%/5%/10%/20%
■ Automatic identification of open / short calibration function
■ Recording function of data-hold and Max./Min./Average value
■ Practical function configuration options and work state hold capacity
■ Standard Mini-USB communication interface and SCPI command set
-
Function Test Parameter Primary parameters: L / C / R / Z Secondary parameters: D / Q / θ / ESR Equivalent Circuit Serial, Parallel Parameter and Equivalent Mode Hold/ Auto Range Mode Auto Measurement Terminals 3-terminal, 5-terminal Measuring Speed 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow) Calibration Function Open, short Comparator Function 1%,5%,10%,20% Input fuse 0.1A / 250V Communication interface Mini-USB (virtual serial port) Test signal Test Frequency U822 100Hz, 120Hz, 1kHz (120Hz, actual frequency is 120.048Hz, following is the same) U822A 100Hz, 120Hz, 1kHz, 10kHz U822C 100Hz, 120Hz, 1kHz, 10kHz, 100kHz Test Level 0.6Vrms Output impedance 100 Ω Display Display LCD dual display of Primary-Secondary parameters Backlight Battery-powered: when the backlight is on, the brightness is reduced by one half after 15 seconds and the light is automatically off after 30 seconds. Power adapter: the backlight is normally on, manual shutoff is needed. Reading Max. reading of primary parameters: 40,000 counts; secondary parameters: D/Q/ θ Minimum resolution: 0.0001 Hightest test accuracy 0.1% Display Range L 0.001uH --- 1000.0 H C 0.001pF --- 20.000mF R/Z 0.0001Ω --- 10.000MΩ Equivalent Series Resistance (ESR) 0.0000Ω -- 999.9Ω Loss factor D 0.0000 -- 9.999 Quality factor Q 0.0000 -- 9999 Phase angle θ -179.9° -- 179.9° Power Requirements Battery model 7.2V Ni-MH 600mAH rechargeable battery AC power adapter Input:220V(1±10%),50Hz(1±5%);Output:12V DC Working current Maximum: 28 mA,Typical working condition of 1kHz frequency: 25mA (100Ω load)) Standby Current Max.: 2μA Battery life 24 hours (typical), nickel - hydrogen battery, with backlight off Charging time and current Single continuous charging time: 200min (maximum).Charging current: 42mA Auto power off(Effective battery) 5min, 15min, 30min, 60min, OFF available; Factory Default : 5min Battery capacity indicator Real-time battery capacity indication General specification Working Environment Temperature 0°C -- 40°C Relative humidity ≤ 90% R.H. Weight 460g Dimension (H × W × D) 192mm × 93mm × 44mm Safety and electromagnetic compatibility IEC 61010-1:2001; IEC 61326-2-1:2005 -
U822C Handheld LCR meter
-
U26010 Gilded short plate U26027 Four terminal Kelvin test clip leads U26029 SMD 4-terminal Kelvin test tweezers U26028 The AC power adapter U26031 7.2V NI-MH battery (built-in host)
-
U26030 Mini-USB通讯线
Recommended products
AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)
DC test: 0.05kV-6kV ±(2% reading+5 digits)
Output channel: 0.05kV – 1kV ±(1.0% reading+2V)
Grouping test function: AC
Interface configuration: PLC,RS232C
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Mid), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω
Online Message