Product Center

+
  • be38d6ff-b658-45ba-b277-dfb47f230e3b.jpg

U9311 Hipot Tester


Insulation resistance test: No
AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)
DC test: 0.05kV-6kV ±(2% reading+5 digits)
Output channel: 0.05kV – 1kV ±(1.0% reading+2V)
Grouping test function: AC
Interface configuration: PLC,RS232C

keywords: LCR Meter Capacitance Meter


product details


  • 产品描述
  • Technical parameters
  • Order information
  • Instrument accessories
  • Optional accessories
  • Video data
    • Commodity name: U9311 Hipot Tester
    • Commodity ID: 1070427616940019712

    Insulation resistance test: No<BR> AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)<BR> DC test: 0.05kV-6kV ±(2% reading+5 digits)<BR> Output channel: 0.05kV – 1kV ±(1.0% reading+2V)<BR> Grouping test function: AC<BR> Interface configuration: PLC,RS232C

    Features

    ■ U9311 series: AC: 0-5kV/0-12mA DC: 0-6kV/0-5mA

       U9321            AC: 0-5kV/0-20mA DC: 0-6kV/0-10mA

                              IR: 0.05kV-1.0kV, 1MΩ-50GΩ

    ■ 480*272 dot-matrix,TFT-LCD display

    ■ Multi-step test results display in the same screen

    ■ Current Off-set function

    ■ Rapidly discharging and ARC detection

    ■ Ground Fault Interrupt(GFI)

    ■ Randomly set voltage rising time and testing time; Freely set waiting time for insulation resistance test

    ■ Storage of 100 Tests Setups with 100 Steps per setup

    ■ Lock keypad fuction

    ■ Standard PLC interface and RS232C interface

     

    Brief Introduction

    U9311 series AC/DC withstanding voltage & insulation resistance tester is an economical and intelligent safety tester with the characteristics of small size, light weight, pleasing appearance and easy operation. U9311 series can be widely used in the safety tests of household appliances, transformer, electronical equipment and components.

     

    General Specifications

    Temperature & Humidity

    0°C - 40°C, ≤90%RH

    Power Requirements

    Voltage

    198V - 242V or 99V - 121V

    Frequency

    47.5Hz - 63Hz

    Power

    ≤100 VA

    Dimension(W×H×D)

    280mm×100mm×400mm

    Weight

    Approx. 11kg 

  • Model

    U9311/U9321

    U9311A

    U9311B

    Withstanding voltage test

    Output Rating

    5kV/12mA

    Functions

    AC/DC/IR

    AC/DC

    AC

    Test Parameters

    AC

    0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)

    DC

    0.05kV-6kV ±(2% reading+5 digits)

    ------------

    Voltage regfulation factor

    ≤(1.0%+5 digits)(Rated power)

    Current test range

    AC

    U9311/U9311A/U9311B: 0.000mA – 12.00mA

    U9321: 0.000mA – 20.00mA

    DC

    U9311A/U9311:0uA – 5.0mA

    U9321:0uA – 10.00mA

    ------------

    Test accuracy

    ±(1% reading+5 digits)

    Discharge function

    Self-discharge after testing(DCW)

    Insulation Resistance Test

    Output voltage

    0.05kV – 1kV ±(1.0% reading+2V)

    ------------

    ------------

    Resistance test range

    1 MΩ-50GΩ

    ------------

    ------------

    Resistance test accuracy

    500V-1000V

    1 MΩ - 1GΩ ±(5% reading+2 digits),

    1 GΩ - 10GΩ ±(10% reading+2 digits)

    10 GΩ - 50GΩ ±(20% reading+2 digits)

    ------------

    ------------

    50V - 500V

    1 MΩ - 1GΩ ±(10% reading+2 digits)

    ------------

    ------------

    Discharge function

    Self-discharge after testing(DCW)

    ------------

    ------------

    Arc detection

    Test range

    AC

    0mA – 15mA

    DC

    0mA -10mA

    ------------

    Other functions

    Voltage rise time

    0.1s – 999.9s

    Test time(AC/DC)

    0.2s – 999.9s

    Voltage wait time(IR)

    0.2s – 999.9s

    ------------

    ------------

    Storage

    Internal:100 groups,100 steps per setup

    External: 500groups

    Interface

    PLC,RS232C

               
  • U9311B AC withstanding voltage tester

    U9311A AC/DC withstanding voltage tester

    U9311/U9321 AC/DC withstanding voltage & Insulation resistance tester

  • U26041 Hight voltage test lead


Recommended products

U9311 Hipot Tester

Insulation resistance test: No
AC test: 0.05kV-5kV ±(2% reading+5 digits)(50、60Hz selectable)
DC test: 0.05kV-6kV ±(2% reading+5 digits)
Output channel: 0.05kV – 1kV ±(1.0% reading+2V)
Grouping test function: AC
Interface configuration: PLC,RS232C

U822C Handheld LCR meter

Test frequency: 100Hz, 120Hz, 1kHz, 10kHz, 100kHz
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω

U822A Handheld LCR meter

Test frequency: 100Hz, 120Hz, 1kHz, 10kHz
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Med), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω

U822 Handheld LCR meter

Test frequency: 100Hz,120Hz,1kHz
Basic accuracy: 0.1%
Test level: 0.6Vrms
Test speed: 10meas/sec(Fast), 5meas/sec(Mid), 2meas/sec(Slow)
Internal bias: -----
Output Impedance: 100 Ω

Online Message

Submit message

Address: B2, Building 23, New Dynamic Business Center,

No. 1, Qingyang North Road, Tianning District, Changzhou

Tel:0086-519-85505199    Fax:0086-519-85505169

E-mail:sales@eucol.com.cn

WeChat

WeChat

Add WeChat

Add WeChat


Business license

Business license